Warning: session_write_close(): php_network_getaddresses: getaddrinfo failed: Name or service not known in /www/wh_eurobio/domains/wap-test.eurobioimaging.eu/lib/simplesaml/lib/SimpleSAML/SessionHandlerPHP.php on line 69 Warning: session_write_close(): php_network_getaddresses: getaddrinfo failed: Name or service not known in /www/wh_eurobio/domains/wap-test.eurobioimaging.eu/lib/simplesaml/lib/SimpleSAML/SessionHandlerPHP.php on line 69 Warning: session_write_close(): php_network_getaddresses: getaddrinfo failed: Name or service not known in /www/wh_eurobio/domains/wap-test.eurobioimaging.eu/lib/simplesaml/lib/SimpleSAML/SessionHandlerPHP.php on line 69 Euro Bioimaging Mass spectrometry-based imaging - Bio* - Euro-BioImaging

Mass spectrometry-based imaging (MSI) - Bio*


Spatially resolved analysis of metabolites, proteins, lipids, peptides, glycans and even drugs has become feasible with the development of mass spectrometry-based imaging strategies. Development and application of these techniques has been pioneered in medicinal and pharmacological research. MSI has allowed, for instance, the detection of novel clinical markers for better diagnosis of cancer tissues and to follow the spatial-temporal patterns of drug molecules used for pharmacological studies at cellular resolution.

Different versions of MSI approaches exist. All of them represent surface analysis techniques which are based on desorption and ionization of molecules followed by their subsequent MS data recording. After collecting a mass spectrum at one spot, the sample is moved to the neighboring spot, and the mass spectrum is sampled again, until the entire sample surface is scanned. By choosing a peak (a distinct m/z value) in the resulting spectra that corresponds to the compound of interest, the MS data is used to map its distribution across the sample. This results in pictures of the spatially resolved distribution of a compound pixel by pixel. Each data set contains a gallery of pictures because any peak in each spectrum can be spatially mapped. MSI therefore has the ability to detect thousands of different analytes in a single experiment. Furthermore, MSI can be applied to any kind of surface, polymers, metal or paper, and of course biological tissues, like histological sections or cells

The most common technique applied for MSI of metabolites and peptides is MALDI MSI, involving the application of a suitable matrix substance on the surface. Spatial resolution achievable is depending on the chosen ionization technique and ranges from few nm (SIMS) to µm (MALDI, LA, DESI). Despite the fact that MSI has been generally considered a qualitative method, the signal generated by this technique is proportional to the relative abundance of the analyte and therefore, quantification is possible, but challenging.

MALDI-MSI of mouse brain and rat retina slices. The localization of phosphatidic acid (PA), phosphatidyl choline (PtdCho), phosphatidyl serine (PtdSer), phosphatidyl ethanolamine (PE) is shown. Courtesy of the Facility of Multimodal Imaging - AMMI Maastricht Node

MSI is available at:

• ALM Italian Node

• Austria BioImaging / CMI

• Facility of Multimodal Imaging - AMMI Maastricht

• NORMOLIM Node

MSI Use cases:

Use cases Node DOI
Proteomics analysis of human intestinal organoids during hypoxia and reoxygenation as a model to study ischemia-reperfusion injury Facility of Multimodal Imaging - AMMI Maastricht https://doi.org/10.1038/s41419-020-03379-9

We use cookies to manage and improve the services of the Euro-BioImaging Web Portal. To find out more, read our Privacy policy.
Please note: For best experience we do not recommend using Internet Explorer.

80